Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | linkun |
Model Number : | Metal Oxide Varistor |
Certification : | CE / ROHS / UL / TUV / SGS |
Price : | Negotiation |
Payment Terms : | T/T, L/C, Western Union |
Supply Ability : | 24 million per year |
Delivery Time : | Negotiation |
Low Leakage Current Varistor The Single Flow Rate Can Reach 70KA Or
Even Higher
The varistor is a voltage limiting protection device. Utilizing the
nonlinear characteristics of the varistor, when an overvoltage
occurs between the two poles of the varistor, the varistor can
clamp the voltage to a relatively fixed voltage value, thereby
realizing the protection of the subsequent circuit. The main
parameters of varistors are: varistor voltage, flow capacity,
junction capacitance, response time, etc.
The response time of the varistor is ns level, which is faster than
the gas discharge tube and slightly slower than the TVS tube.
Generally, it is used for the overvoltage protection of electronic
circuits and its response speed can meet the requirements. The
junction capacitance of varistors is generally on the order of
hundreds to thousands of Pf. In many cases, it is not suitable to
be directly applied to the protection of high-frequency signal
lines. When it is applied to the protection of AC circuits, because
its large junction capacitance will increase the leakage Current
needs to be fully considered when designing the protection circuit.
The flow capacity of the varistor is larger, but smaller than that
of the gas discharge tube. The varistor, referred to as VDR, is a
voltage-sensitive non-linear overvoltage protection semiconductor
component.
Model Number | 14D 20D 181K 390K 431K 470K 471K 511K 561K 680K 681K 821K 102K |
Package | Varistors |
D/C | Newest |
Condition | New & Original |
Lead time | Within 1 day |
Unit Price | Contact us for latest price |
More details | Please contact us |
Model | Maximum continuous working voltage | Varistor voltage | maximum limit Voltage | flow capacity(8/20u s) | maximum energy (J) | rated power | capacitance | ||||
AC(V) | DC(V) | V0.1mA | Vp(V) | lp(A) | 1次(A) | 2次(A) | 10/ 1000us | 2ms | (W) | 1KH Z (pF) | |
MYG-32D391K | 250 | 320 | 390(351-429) | 650 | 200 | 25000 | 20000 | 330 | 3200 | ||
MYG-32D431K | 275 | 350 | 430(387-473) | 710 | 200 | 25000 | 20000 | 360 | 3100 | ||
MYG-32D471K | 300 | 385 | 470(423-517) | 775 | 200 | 25000 | 20000 | 380 | 2800 | ||
MYG-32D511K | 320 | 415 | 510(459-561) | 845 | 200 | 25000 | 20000 | 430 | 2700 | ||
MYG-32D621K | 385 | 505 | 620(558-682) | 1025 | 200 | 25000 | 20000 | 470 | 2400 | ||
MYG-32D681K | 420 | 560 | 680(612-748) | 1120 | 200 | 25000 | 20000 | 495 | 2200 | ||
MYG-32D751K | 460 | 615 | 750(657-825) | 1240 | 200 | 25000 | 20000 | 520 | 2000 | ||
MYG-32D781K | 485 | 640 | 780(702-858) | 1290 | 200 | 25000 | 20000 | 550 | 1900 | ||
MYG-32D821K | 510 | 670 | 820(738-902) | 1355 | 200 | 25000 | 20000 | 580 | 1800 | ||
MYG-32D911K | 550 | 745 | 910(819-1001) | 1500 | 200 | 25000 | 20000 | 620 | 1300 | ||
MYG-32D951K | 575 | 765 | 950(855-1045) | 1570 | 200 | 25000 | 20000 | 650 | 1200 | ||
MYG-32D102K | 625 | 825 | 1000(900-1100) | 1650 | 200 | 25000 | 20000 | 685 | 1100 | ||
MYG-32D112K | 680 | 895 | 1100(990-1210) | 1815 | 200 | 25000 | 20000 | 750 | 1000 | ||
MYG-40D210K | 130 | 170 | 200(185-225) | 395 | 250 | 40000 | 25000 | 310 | 8400 | ||
MYG-40D241K | 150 | 200 | 240(216-264) | 455 | 250 | 40000 | 25000 | 360 | 8000 | ||
MYG-40D271K | 175 | 225 | 270(243-297) | 550 | 250 | 40000 | 25000 | 390 | 7600 | ||
MYG-40D331K | 210 | 275 | 330(297-363) | 595 | 250 | 40000 | 25000 | 460 | 6700 | ||
MYG-40D361K | 230 | 300 | 360(324-396) | 650 | 250 | 40000 | 25000 | 475 | 6200 | ||
MYG-40D391K | 250 | 320 | 390(351-429) | 710 | 250 | 40000 | 25000 | 490 | 5100 | ||
MYG-40D431K | 275 | 350 | 430(387-473) | 775 | 250 | 40000 | 25000 | 550 | 4900 | ||
MYG-40D471K | 300 | 385 | 470(423-517) | 845 | 250 | 40000 | 25000 | 600 | 4300 | ||
MYG-40D511K | 320 | 415 | 510(459-561) | 1025 | 250 | 40000 | 25000 | 640 | 4200 | ||
MYG-40D621K | 385 | 505 | 620(558-682) | 1120 | 250 | 40000 | 25000 | 720 | 3800 | ||
MYG-40D681K | 420 | 560 | 680(612-748) | 1240 | 250 | 40000 | 25000 | 750 | 3500 | ||
MYG-40D751K | 460 | 615 | 750(675-825) | 1290 | 250 | 40000 | 25000 | 780 | 3200 | ||
MYG-40D781K | 485 | 640 | 780(702-858) | 1355 | 250 | 40000 | 25000 | 820 | 3000 | ||
MYG-40D821K | 510 | 670 | 820(738-902) | 1500 | 250 | 40000 | 25000 | 900 | 2900 |
Application
1. Varistor voltage: refers to the voltage value across the
varistor at a specified temperature and DC (generally 1mA or
0.1mA). Recorded as V1mA or V0.1mAo
2. Maximum continuous voltage: refers to the maximum effective
value of sinusoidal AC voltage or the maximum DC voltage value that
can be continuously applied to both ends of the varistor for a long
time under the specified ambient temperature
3. Limiting voltage: refers to the maximum peak voltage at both
ends of the varistor when a specified surge current (8,20μs) passes
through it.
4. Rated power: refers to the maximum average impact power that can
be applied to the varistor under the specified ambient temperature.
5. Maximum energy: the maximum impact energy that can be applied to
the varistor under the condition that the varistor voltage does not
change more than ±10% and the impulse current waveform is 10,
1000μs or 2ms.
6. Current capacity (maximum inrush current)
![]() |